T9000S Water Supply Specific Inverter

T9000S Water Supply Specific Inverter
T9000S Water Supply Specific Inverter

T9000S Water Supply Specific Inverter

 

ZONCN T9000S is a dedicated constant pressure water supply VFD with built-in PID, multi-pump cycle control and intelligent energy-saving sleep mode. It ensures stable pipeline pressure, eliminates water hammer and reduces pump operation costs, ideal for building water boosting, municipal water supply and industrial water treatment systems.
  • 商品编号 :

    T9000S
  • 订单(最小起订量) :

    20
  • 支付 :

    Paypal/TT/Western Union
  • 产品来源 :

    Shanghai, China
  • 颜色 :

    Black
  • 交货时间 :

    18-30 days
  • 重量 :

    200kg

ZONCN T9000S series is a water-supply dedicated variable frequency drive developed exclusively for constant-pressure water pump systems, built on high-performance open/closed-loop vector control technology. It integrates mature water supply logic, independent PID regulator, multi-pump switching cycle control, sleep/wake-up energy-saving mode and complete pump protection functions in one unit.

Designed for municipal water supply, high-rise building booster, industrial circulating water, sewage treatment and fire-fighting water systems, T9000S automatically adjusts pump speed according to real-time pipe network pressure to maintain stable constant water pressure, drastically cutting power consumption, reducing pipeline water hammer impact and extending pump service life.

Product Features

  • All-in-One Built-in Constant Pressure PID
  • Multi-Pump Cycle Parallel Control
  • Intelligent Sleep & Wake Energy-Saving Mode
  • Anti-Water Hammer Soft Start & Soft Stop
  • Dedicated Pump Fault Protection Logic
  • User-Friendly Water Supply Parameter Presets

Technical Specifications

Item

T9000S Specification

Basic function

Control mode

V/F control

Open loop vector control (without PG);

Closed loop vector control (with PG).

Maximum frequency

0.00-600.00Hz.

Carrier frequency

0.5kHz~8kHz

The carrier frequency is automatically adjusted based on the load features.

Input frequency resolution

Digital setting:0.01Hz

Analog setting: Maximum frequency 0.025%

Start torque

G-type:0.5Hz/150%(no PG);

P-type :0.5Hz/100%

Speed range

1:100(No PG)

Speed stability accuracy

±0.5%(No PG)

Basic function

Overload capacity

G Type:60s for 150% of the rated current, 3s for 180% of the rated current.

P Type:60s for 120% of the rated current, 3s for 150% of the rated current.

Torque boost

Auto-boost ; Customized boost:0.1%~30.0%.

VF curve

Straight-line VF curve; Multi-point VF curve; N-power VF curve (1.2 power, 1.4 power, 1.6 power, 1.8 power, 2 power)

VF separation

2 types: complete separation;half separation.

Ramp Mode

Linear or S-curve acceleration and deceleration mode. Four kinds of acceleration and deceleration time, acceleration and deceleration time range 0.0~6500.0s.

DC braking

Dc braking frequency :0.00Hz~ maximum frequency;Braking interval :0.0s~36.0s ;Braking action current value :0.0%~100.0%

JOG control

Jog frequency range:0.00~50.00Hz

Jog acceleration/deceleration time:0.0~6500.0s

Simple PLC; Multi-speed operation

Up to 16 segment speeds are possible with built-in PLC or control terminals.

Built-in PID

It is convenient to realize the closed-loop control system of process control.

Automatic Voltage Regulation (AVR)

When the grid voltage changes, it can automatically keep the output voltage constant.

Overvoltage and overcurrent stall control

Automatic current and voltage limit during operation to prevent frequent overvoltage skipping.

Rapid current limiting function

Minimize the overcurrent fault and protect the normal operation of the inverter.

Torque limit and control

Automatic torque limit during operation to prevent frequent overcurrent tripping; The closed-loop vector mode(FVC) enables torque control.

Characteristic function

Excellent performance

The control of asynchronous motor is realized with high performance current vector control technology.

Instant stop non-stop function

The load feedback energy is used to compensate the voltage reduction in the transient power failure, and the inverter can continue to run for a short time.

Rapid current limit

It helps to avoid frequent over current faults of the AC drive.

Timing control

Timing range:0.0Min-6500.0Min.

Communication

Modbus RS485;

Running

Command source

Operation panel, control terminal, serial communication port. Users can switch in a variety of ways.

Frequency source

10 frequency sources: digital set, analog voltage set, analog current set, pulse set, serial port set. Users can switch in a variety of ways.

Auxiliary frequency source

10 auxiliary frequency sources. Users can flexibly realize auxiliary frequency fine-tuning and frequency synthesis.

Input terminal

Standard :5(1PH 220V 0.4kW-3.7kW-vector control /3PH 380V 0.4kW-5.5kW vector control) / 6(7.5kW or more) digital input terminals, The S3 supports high-speed pulse input up to 100kHz;

1 (below 5.5KW) / 2 (above 7.5KW) analog input terminals, 1 support 0-10V voltage input, 1 (above 7.5KW) support 0-10V voltage input or 4-20mA current input.

Output terminal

1 high-speed pulse output and collector output terminals ;

1(below 5.5KW)/2(above 7.5KW) relay output terminal;

1(1PH 220V 0.4kW-3.7kw-vector /3PH 380V 0.4KW-5.5KW vector)/ 2(7.5KW or more) analog output terminal, support 4~20mA current output or 0~10V voltage output.

Protection

Protection function

Short-circuit detection, input and output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection, overload protection, etc.

LED display

Good display of parameters

Key locking and function selection

It can lock the keys partially or completely and define the function range of some keys so as to prevent mal-function.

Environment

Installation location

Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.

Altitude

<1000m

Ambient temperature

-10°C ~+ 40°C ( de-rated if the ambient temperature is between 40°C ~50°C)

Humidity

Less than 95%RH, without condensing

Vibration

Less than 5.9m/s²(0.6g)

Storage temperature

-20~+60℃

 

Specifications

Model

Rated output power (kW)

Rated input current (A)

Rated output current (A)

Motor Power (kW)

Input voltage(v):1PH AC 220V±15%

T9200S-0R4G

0.4

5.4

2.10

0.4

T9200S-0R75G

0.75

7.2

3.80

0.75

T9200S-1R5G

1.5

10

7.20

1.5

T9200S-2R2G

2.2

16

9.00

2.2

T9200S-3R7G

3.7

17

17.00

3.7

T9200S-5R5G

5.5

26

25.00

5.5

T9200S-7R5G

7.5

35

32.00

7.5

Input voltage(v):3PH AC 380V±15%

T9400S-0R4G

0.4

3.4

1.51

0.4

T9400S-0R75G

0.75

3.8

2.1

0.75

T9400S-1R5G

1.5

5

3.8

1.5

T9400S-2R2G

2.2

5.8

5.1

2.2

T9400S-3R7G/5R5P

3.7/5.5

10/15

9/13

3.7/5.5

T9400S-5R5G/7R5P

5.5/7.5

15/20

13/17

5.5/7.5

T9400S-7R5G/11P

7.5/11

20/26

17/25

7.5/11

T9400S-11G/15P

11/15

26/35

25/32

11/15

T9400S-15G/18.5P

15/18.5

35/38

32/37

15/18.5

T9400S-18.5G/22P

18.5/22

38/46

37/45

18.5/22

T9400S-22G/30P

22/30

46/62

45/60

22/30

T9400S-30G/37P

30/37

62Z76

60/75

30/37

T9400S-37G/45P

37/45

76/90

75/90

37/45

T9400S-45G/55P

45/55

92/113

90/110

45/55

T9400S-55G

55

113

110

55

T9400S-75P

75

157

152

75

T9400S-75G/90P

75/90

157/180

152/176

75/90

T9400S-90G/110P

90/110

180/214

176/210

90/110

T9400S-110G/132P

110/132

214/256

210/253

110/132

T9400S-132G/160P

132/160

256/307

253/300

132/160

T9400S-160G/185P

160/185

307/355

300/340

160/185

T9400S-185G/200P

185/200

355/385

340/380

185/200

T9400S-200G/220P

200/220

385/430

380/420

200/220

T9400S-220G/250P

220/250

430/475

420/470

220/250

T9400S-250G/280P

250/280

475/525

470/520

250/280

T9400S-280G/315P

280/315

525/610

520/600

280/315

T9400S-315G/350P

315/350

610/665

600/640

315/350

T9400S-350G/400P

350/400

665/730

640/690

350/400

T9400S-400G/450P

400/450

730/825

690/790

400/450

T9400S-450G/500P

450/500

825/865

790/860

450/500

T9400S-500G/560P

500/560

865/960

860/950

500/560

T9400S-560G/630P

560/630

960/1112

950/1100

560/630

T9400S-630G/710P

630/710

1112/1290

1100/1280

630/710

 

Featured features

 

Water Supply

Function

Description

Code display

Add pump

If the operating frequency is higher than the Add pump frequency PA.51, and the feedback is less than 95% of the set value, and the duration is longer than the Add pump time PA.52, the current pump will be switched to commercial power supply frequency operation mode, and inverter starts the next pump .

 

Reduce Pump

When the operating frequency is less than the Reduce Pump frequency PA.53, and the feedback is higher than 95% of the set value, and the duration is longer than the Reduce Pump time PA.54,  the earliest  commercial power supply pump will be stopped.

 

switch pump

When the inverter pump is running, and the duration reaches the pump replacement time, it will be switched to the next pump.

 

The function of terminal stop pump

Stop the water pump function with multi-function terminal  

51:  Pump 1 invalid

52:  Pump 2 invalid

53:  Pump 3 invalid

54:  Pump 4 invalid

When the corresponding input terminal is closed

1) If the pump is running at the commercial power supply frequency, immediately disconnect the motor,

2) If the pump is running at inverter frequency and there are idle pumps, immediately enter the pump switching mode.

3) If the pump is running at inverter frequency and there is no idle pump, the commercial power supply pump will stop, and after the delay time, switch to variable frequency running.

 

Auto start when power on

Power-on auto start delay time PA.38,

PA.38=0 power-on auto start is invalid;

 PA.38 factory default value is 0

 

Pressure setting and display

Digital tube “setting pressure, feedback pressure” at the same time, the unit is Bar; can shift to display other contents

Press the up and down keys to adjust the pressure mode, refer to the parameters of PA.00

PA.00=0: digital target value PA.01

PA.00=3: digital target value PA.01, which can be set with the up and down keys; the pressure screen will be displayed when changing

 

PID sleeping function

1) When the pressure is reached, the running frequency is less than the sleeping frequency PA.29 and the duration is longer than the sleeping time PA.30,  the frequency becoming 0, it enter into sleeping state and displays "SLP"

2) When the running frequency is higher than the sleeping frequency PA.29, and the frequency is stable, and it will also enter into the sleeping state. Refer to parameters PA.45~PA.48

3) If the frequency is higher than PA.49, sleeping function is invalid.

4) Sleep only when one inverter pump is running

SLP

PID wake-up or water leak detection function

Under sleeping mode, if the pressure drop deviation is bigger than the set pressure setting PA.31, the inverter wakes up and PID function starts.

 

Anti-freeze

Under sleeping mode, if the duration is longer than PA.42, inverter will wake up and run with time of PA.43 at the frequency of PA.42.

 

Pressure sensor disconnect detection

 When pressure sensor disconnect, inverter will alarm and display “PIDE”, Refer to the parameter of PA26, PA27

PIDE

High water pressure warning

When the pressure is higher than PA.32 and the duration is longer than 0.1S, alarm high pressure fault and stop, the fault code is "HP", (after the pressure returns to normal, delay PA.35 and automatically reset the fault)

HP

Low water pressure warning

When the pressure is lower than PA.33 and the duration is longer than PA.36, alarm low pressure fault and stop, the fault code is "LP", (after the pressure returns to normal, delay PA.35 and automatically reset the fault)

LP

No water warning

"Detection frequency A" =maximum frequency P0.12 - 2Hz

If the frequency of the inverter is higher than "detection frequency A",  the duration is longer than PA.37 and the pressure is less than PA.34, it will alarm no water fault and stop, and the fault code is "LL"

LL

No Water fault auto reset function

When no water fault occurs, the inverter will automatically reset the fault and run, and the automatic reset interval time refers to PA.39. PA.40.

Auto stop when there is no water, , and automatically resume the water supply when water comes.

(In the keyboard operation mode,need to turn on the automatic power-on and automatic operation function )

 

 

 

Dimension

Size A

Size B

 

Size

Model

W

H

D

A

B

Φd

A

T9200S-0R4G

T9200S-0R75G

T9200S-1R5G

72

142

127

130

61

4.5

T9400S-0R4G

T9400S-0R75G

T9400S-1R5G

T9400S-2R2G

T9200S-2R2G

T9200S-3R7G

85

180

131

167

72

5.5

T9400S-3R7G/5R5P

T9400S-5R5G/7R5P

B

T9200S-5R5G

T9400S-7R5G/11P

T9400S-11G/15P

106

240

168

230

96

4.5

T9200S-7R5G

T9400S-15G/18.5P

T9400S-18.5G/22P

T9400S-22G/30P

151

332

183

318

137

7

T9400S-30G/37P

T9400S-37G/45P

217

400

216

385

202

7

 